Object 6200h: cyclic timer, Object 6300h: cam state register, Object 6301h: cam enable register – BEI Sensors MHK5 Absolute Hollow Shaft Encoder User Manual
Page 48: Object 6302h: cam polarity register
Version 07/10
BEI Sensors CANopen Manual serie M
48
Object 6200h: Cyclic timer
This object contains the value of the event timer of the corresponding TPDOs. The value can be changed
between 1-65538 ms.
Subindex Description
Data Type
Default Value
Access
Restore after
BootUp
0h
Cyclic Time
Unsigned 16
64h
rw
yes
The object 6200h is hard-wired to the objects 1800h subindex 5h and 2200h and provide the cycle time for
the cyclic mode. (See chapter Cycle Time and Event Timer)
Object 6300h: Cam state register
This object contains the cam state register. The subindices 1h to FEh contain the cam state of channel 1 to
254.
Subindex Description
Data Type
Default Value
Access
Restore after
BootUp
0h
Number of sub indices
Unsigned 8
1h
ro
1h
Cam state channel 1
Unsigned 8
4h
romap
yes
Object 6301h: Cam enable register
This object contains the cam enable register
Subindex Description
Data Type
Default Value
Access
Restore after
BootUp
0h
Number of sub indices
Unsigned 8
1h
ro
1h
Cam enable channel 1
Unsigned 8
rw
yes
Object 6302h: Cam polarity register
This object contains the cam enable register
Subindex Description
Data Type
Default Value
Access
Restore after