beautypg.com

BEI Sensors HS52 Incremental Explosion Proof Encoder User Manual

Bei sensors, Hs52 incremental ordering options, Hs52 abzc sc

background image

 

Tel: 805-968-0782 /800-350-2727 | Fax: 805-968-3154 /800-960-2726 | 7230 Hollister Ave., Goleta, CA 93117-2807 |

www.beisensors.com

These commodities, technology or software if exported from the United States must be in accordance with the Bureau of Industry, and Security, Export Administration regulations. Diversion contrary to U.S. law is prohibited.

 

SPECIAL FEATURES:

S = Special

features specified

on purchase order

(consult factory)

 

 

Mechanical Specifications

Allowable Misalignment: SP11 Flex Shaft is designed
to accommodate up to 0.04” T.I.R radial and ±0.02 axial;
Consult factory for other shaft options
Starting Torque at 25°C: Blind shaft version (BS) = 10

in-oz (max)
Bearings: 52100 high carbon steel.

Shaft Material: 416 stainless steel
Bearing Housing: Die cast and machined aluminum
with dichromate finish standard. Hard anodized finish

available.
Cover: Die cast and machined aluminum.
Bearing Life: 7.5 X 10

9

revs (50,000 hrs at 2500 RPM)

Maximum RPM: 6,000 MAX. (Temp. Derated 5ºC/1,000
RPM above 2,000 RPM for continuous operation)

Moment of Inertia:
Blind Shaft = 8.6 x 10

-3

oz-in-sec

2

*

*with spline flex shaft option
Weight: Approx. 3.3 lbs or 1.5 kg

BEI Sensors

 

Electrical Specifications

Code: Incremental (Absolute option available)
Output Format: 2 channels in quadrature, 1/2 cycle
index gated with negative B channel
Cycles Per Shaft Turn: 1 to 80,000 (see table 1) For
resolutions above 5,000 see BEI for interpolation options
Supply Voltage: 5 to 28 VDC available
Current Requirements: 100 mA typical +output load,
250 mA (max)
Voltage/Output: (see note 3)
28V/V: Line Driver, 5–28 VDC in, Vout = Vin
28V/5: Line Driver, 5–28 VDC in, Vout = 5 VDC
28V/OC: Open Collector, 5–28 VDC in, OCout
Protection Level: Reverse, overvoltage and output short
circuit
Frequency Response: 100 kHz, up to 1MHz with
interpolation option (see note 5)
Output Terminations: Side conduit
Note: Consult factory for other electrical options


Environmental Specifications

Enclosure Rating: IP66
Hazardous Area Rating:
Class I, Div 1, Groups C and D
CENELEC/ATEX Gas Groups
IECEx certified
Temperature: Operating, 0 to 70ºC; extended
temperature testing available (see note 6); 80ºC max;
storage -25 to 90ºC.
Shock: 50 g’s for 11 msec duration
Vibration: 5 to 2000 Hz @ 20 g’s
Humidity: 100% RH without condensation
NOTES & TABLES: All notes and tables referred to in the
text can be found on the back of this page.

HS52 Incremental Ordering Options

for assistance, call 800.350.2727

Use this diagram, working from left to right to construct your model number (example: HS52-SP11-BS-1024-ABZC-28V/V-SC-CEN)

All notes and tables referred to can be found on the back of this page.

 

TYPE

:

HS = Hollow Shaft

52 = 5.2”Dia.

FLEX SHAFT BORE:

SP11 = 11 tooth spline bore

SHAFT

CONFIGURATION:

BS = Blind Shaft

CYCLES PER TURN:

See Table 1, next page

NO. OF CHANNELS:

ABZC = Dual Quad w/ Index

and complements

OUTPUT

TERMINATION:

SC = dual ¾” – 14 NPT in sides of term. box

EN 55011 and EN 61000-6-2

CENELEC/ATEX : Ex d IIB T4 Gb

UL: Class I, Div 1, Group C & D

Model HS52 Explosion Proof
Hollow Shaft Incremental Encoder

 

 

VOLTAGE / OUTPUT:

28V/V = 5-28 Vin/out

28V/5 = 5-28 Vin/5Vout

28V/OC = 5-28Vin/OCout

 

Pictured with hard anodized finish special feature 

CERTIFICATION:

CEN = UL Class I Div 1 and

CENELEC/ATEX

EXD = CENELEC/ATEX only

Blank = not certified

HS52

ABZC

SC

The HS52 is the industry’s first UL and ATEX rated explosion proof hollow shaft
encoder. Capable of operating directly in Division 1 or Zone 1 environments, the
HS52 does not need an Intrinsic Safety barrier. This provides a simpler, more
streamlined feedback system in explosion proof environments worldwide. Fitted with
a flex shaft in the bore, the HS52 housing can be rigidly mounted, preventing stress to
encoder bearings and providing a more secure attachment for the required hazardous
area conduit fittings. Additionally, the compact hollow shaft design provides
engineers space saving advantages over traditional shafted encoders.

The HS52 is the ideal position sensing solution for use in oil and gas industries,
solvent refining operations, spray painting applications, and explosive environments
where space is limited and operating conditions are extreme.

IECEx UL 11.0009X

 

BS