STM-1/OC-3 (155.520 Mb/s) J2912B

General

This optical interface comprises a plug-in module (J2912B) suitable for plugging

into the J2300C/D/E Agilent Advisor mainframe and J2900A High Speed

undercradle. The interface handles ATM and Packet over SONET/SDH (PoS).

Common to Inputs and Outputs:

Connectors: SC-PC

Framing:

SDH: STM-1

SONET: STS-3c

SONET/SDH Frame Scrambling (x

7

+ x

6

+ 1)

STM-1: ITU-T G.707

SONET: ANSI T1.105

ATM Cell Scrambling: conforms to ITU-T I.432.1 (x

43

+ 1) and may be turned on

or off;

PoS analysis configurations supported:

IETF PPP in HDLC: RFC 1662 and both current RFC 2615 (x

43

+ 1

scrambled SONET/SDH payload) and obsolete RFC 1619 (unscrambled

SONET/SDH payload) versions with version auto-detect based on POH

C2 byte value (default) and manual over-ride for scrambling enable/disable

Cisco HDLC over SONET/SDH

FCS-16 (default) and FCS-32

Inputs:

Two ports (single-mode/multi-mode compatible)

Sensitivity:

Typ. -32 dBm

Min. -28 dBm

Loss of Signal Detect Level:

-34 dBm

Real-time optical power measurement

(can also be used to measure at 622Mb/s):

+3 dBm to -42 dBm dynamic range

+/-0.5 dB absolute accuracy

Physical layer alarms and statistics (SDH / SONET):

Loss of Signal (LOS) (*)

Loss of Frame (LOF) (*)

B1, B2, B3 BIP errors

Summary BIP error (*)

MS-REI/REI-L (Line FEBE)

REI/REI-P (Path FEBE)

MS-RDI/RDI-L (Line FERF) (*)

MS-AIS/AIS-L (*)

RDI/RDI-P (Yellow)

AIS/AIS-P

Summary Far End (*)

Loss of Cell Delineation (LCD) (*)

ATM layer statistics:

Auto-discovery of up to 1024 VCs and collection of statistics on each

Average utilization in percent

Instantaneous utilization in percent

Maximum utilization in percent

Total cells received

Idle/unassigned cells received

Busy (assigned) cells received

Header (“HEC”) errors

ATM and WAN Interface