Frame relay – Atec Agilent-J2300E User Manual
Page 26
26
The Advisor transmits controlled packets into the network according to an
established traffic contract between the user and the network, defined by the
Frame Relay Forum FRF.13. This application characterizes the reliability of
the Frame Relay Network by simulating user traffic and optional background
traffic.
There are three possible configurations:
Transmission of traffic between two advisors connected from end to end
Physical network loopback utilizing only one Agilent Advisor
Generation of IP-ICMP requests from the Agilent Advisor to a network device
This test runs with LMI emulation off or on for the following options:
UNI-User (CPE) Emulation
UNI-Network (Switch) Emulation
NNI Emulation (bi-directional polling)
The following FRF.13 statistics are provided:
All Frames delivered
Bc Frames delivered
Be Frames delivered
All Data delivered
Bc Data delivered
Be Data delivered
Min, Mean, and Max Transfer Delay
Availability
The following T1.606 statistics are provided:
Total Frames
Total Data
Total Lost Frames
Misdelivered Frames
DE=1 CIR Frames. Frames marked for possible discard by switch
DE=0 EIR Frames. Frames that should have been marked for discard but
werent.
Frame Relay