beautypg.com

Atec Agilent-J2300E User Manual

Page 71

background image

71

ATM QoS measurements (to ITU-T O.191)

ATM Traffic contract conformance (policing) measurements

Frame Relay SLA measurements (to FRF.13)

Frame Relay CIR measurements

Capture buffer size: 64 Mbyte on each receiver

Capture buffer timestamp resolution: 100 ns

Capture rate: Full line rate

Analyze bit error ratio (BER) patterns in the

physical layer frame payload or in the ATM cell payload:

1111, 1010, 1100, PRBS 2

15

- 1, PRBS 2

20

- 1, PRBS 2

23

- 1

Outputs:

Two ports, 75 Ohm unbalanced

Levels:

ITU-T G.703

Clocking:

Recovered (loop), and Internal or External (using other receiver input)

Internal clock rate accuracy:

+/- 20 ppm

Alarm generation:

Remote Alarm Indication (RAI), formerly known as FERF

Alarm Indication Signal (AIS)

Simulate line or equipment

Generate ATM Test Cell traffic (to ITU-T O.191) shaped to traffic contract

Generate from cell table

Generate Frame Relay SLA traffic (to FRF.13)

Generate bit error ratio (BER) patterns in the

physical layer frame payload or in the ATM cell payload:

1111, 1010, 1100, PRBS 2

15

- 1, PRBS 2

20

- 1, PRBS 2

23

– 1

Transmission of 4000 byte BER user pattern in WAN