beautypg.com

Atm and wan interface specifications – Atec Agilent-J2300E User Manual

Page 68

background image

68

E1 (2.048 Mb/s) / T1 (1.544 Mb/s) J2294D

General

This interface is a plug-in module suitable for plugging into the J2300C/D/E

Agilent Advisor mainframe and the J2900A High Speed undercradle. The

J2294D has DB-9 and RJ-45 connectors, which, with converter cables, can

connect to 120 Ohm Small Siemens connectors. This module handles

frame- and cell-based technologies such as ATM, Frame Relay, HDLC, SDLC,

X.25, ATM DXI, and PPP in addition to BERT.

This module can be configured as a T1 (1.544 Mb/s) or as an E1 (2.048 Mb/s)

interface. For T1 information, see J2298D specifications.

Common to Inputs and Outputs:

Connectors:

Balanced 120 Ohm DB-9 and RJ-45

Line Code:

ATM: HDB3

WAN: HDB3, AMI

Electrical:

ITU-T G.703, G.704

Framing:

ATM and WAN

ITU-T G.704 alternate framing with or without CRC-4

Fractional channel, any multiple of 64 kb/s channel

Unframed at 2.048 Mb/s

Cell Mapping:

Direct (ITU-T G.804)

Cell Scrambling:

Conforms to ITU-T I.432.1 (x

43

+ 1)

Inputs:

Two ports

Levels:

ITU-T G.703

Received pulse amplitude measurement (mVpeak)

Monitor modes:

Terminated, 120 Ohm balanced

Bridged (High Impedance)

Monitor Jack -20 dB and -30 dB

Physical Layer Alarms and Statistics:

Loss of Signal (LOS)

Loss of Frame (LOF)

Alarm Indication Signal (AIS)

Remote Alarm Indication (RAI)

Line code violations

CRC-4 errors (if CRC-4 is selected)

Frame alignment error

Loss of Cell Delineation (LCD)

IMA Control Protocol (ICP) decoding supported

ATM Layer Statistics:

Auto-discovery of up to 1024 VCs and collection of statistics on each

Average utilization in percent

Instantaneous utilization in percent

Total cells received

Idle/unassigned cells received

Busy (assigned) cells received

Header (“HEC”) errors

ATM and WAN Interface
Specifications