Atec Agilent-J2300E User Manual
Page 67
67
Frame Relay Statistics:
Average utilization in percent
Instantaneous utilization in percent
Maximum utilization in percent
Minimum utilization in percent
Total frames
Total octets
Average throughput (bps)
Instantaneous throughput (bps)
Maximum throughput (bps)
Minimum throughput (bps)
Aborted frames
Short frames
FCS errors
ATM QoS measurements (to ITU-T O.191)
ATM Traffic contract conformance (policing) measurements
Frame Relay SLA measurements (to FRF.13)
Frame Relay CIR measurements
Capture buffer size: 64 Mbyte on each receiver
Capture buffer timestamp resolution: 100 ns
Capture rate: Full line rate
Analyze bit error ratio (BER) patterns in the
physical layer frame payload or in the ATM cell payload:
1111, 1010, 1100, PRBS 2
15
- 1, PRBS 2
20
- 1, PRBS 2
23
- 1
Outputs:
Two ports, 100 Ohm balanced
RJ-11 handset jack (for WAN)
Interface types (and output levels):
DSX-1 (build-out selectable from 0 to 655 ft in 5 steps)
Network Interface (selectable LBO levels, 0, -7.5 dB and -15.0 dB)
Electrical:
ITU-T G.703, G.704
Clocking:
Recovered (loop), Internal or External (using other receiver input)
Internal clock rate accuracy:
+/- 20 ppm
Alarm generation:
Remote Alarm Indication (RAI), formerly known as FERF
Alarm Indication Signal (AIS)
Simulate line or equipment
Generate Test Cell traffic (to ITU-T O.191) shaped to traffic contract
Generate from cell table
Generate Frame Relay SLA traffic (to FRF.13)
Generate bit error ratio (BER) patterns in the
physical layer frame payload or in the ATM cell payload:
1111, 1010, 1100, PRBS 2
15
- 1, PRBS 2
20
- 1, PRBS 2
23
1