beautypg.com

Atm and wan interface specifications – Atec Agilent-J2300E User Manual

Page 76

background image

76

DS3 (44.736 Mb/s) J3759B

General

This interface comprises a plug-in module (J3759B) suitable for plugging into

the J2300C/D/E Advisor mainframe and the J2900A High Speed undercradle.

The J3759B supports both ATM and frame-based technologies Frame Relay

(CIR & SLA), HDLC, PPP in addition to BERT. This module can also be

configured for use as an E3 (34.368 Mb/s) interface; see above for details.

Common to Inputs and Outputs:

Connectors: 75 Ohm BNC female

Electrical: ITU-T G.703

Line Code: B3ZS

Framing:

Frame Relay: C-bit and M13 (auto-select on input side)

ATM: C-bit framing

Cell Mapping:

Direct (normal mode, ITU-T G.804)

PLCP (obsolescent mode, ITU-T G.804)

Cell Scrambling:

conforms to ITU-T I.432.1 (x

43

+ 1) and may be turned on or off

Inputs:

Two ports,

Levels:

Auto gain control for high, DSX-3, low, and monitor jack

(min. = DSX -23 dB); all unbalanced 1.2 V peak to 26 mV,

34 dB dynamic range

Received pulse amplitude measurement (mVpeak) (WAN only)

Monitor modes:

Terminated/Repeater (75 Ohm)

Bridged (high impedance)

Physical Layer Alarms and Statistics:

Loss of Signal (LOS)

Loss of Frame (LOF)

Alarm Indication Signal (AIS)

Remote/yellow X-bit

Line code violations

Far End Block Error (FEBE)

Idle

P1/P2 parity errors

C-bit parity errors

Far End Alarm and Control (FEAC):

DS3 Line

LOS/HBER

Out of Frame (OOF)

AIS received

Idle signal received

Service failure

No service failure

Common equipment failure

Line loopback activate

Line loopback de-activate

PLCP sync loss

PLCP yellow (Path FERF)

PLCP BIP

PLCP FEBE

Loss of Cell Delineation (LCD)

ATM and WAN Interface
Specifications