Frame relay – Atec Agilent-J2300E User Manual
Page 43
43
T1/DS1
Loss of signal (LOS) (*)
Loss of frame (LOF) (*)
Loss of PLCP sync (LOPS) (*)
AIS (*)
RAI/Yellow (X-bits) (*)
Bi-polar violations
ESF CRC errors
Line code violation (B8ZS)
Frame slips
Frame bits
Ones density
Excess zeros
E1
Loss of Signal (LOS) (*)
Loss of Frame (LOF) (*)
Line code violations (HDB3)
RAI (FERF) (*)
AIS (*)
CRC-4 errors (if CRC-4 is selected)
Frame alignment error
E3
Loss of signal (LOS) (*)
Loss of frame (LOF) (*)
BIP-8
Line code violations (HDB3)
Payload type mismatch
REI (FEBE)
RDI (FERF)
AIS (*)
T3/DS3
Loss of Signal (LOS) (*)
Loss of Frame (LOF) (*)
Remote/Yellow (X-bits) (*)
AIS (*)
Line code violations (B8ZS)
FEBE
Idle (*)
P1/P2 parity errors
C-bit parity errors
PLCP sync loss (*)
PLCP Yellow (*)
PLCP BIP
PLCP FEBE
FEAC (*)
FEAC DS3 line
FEAC loss of signal/HBER
FEAC loss of frame
FEAC AIS
FEAC idle
FEAC service failure
FEAC no service failure
FEAC common equipment failure
FEAC line loopback activate
FEAC line loopback de-activate
Signal Strength Pulse Amplitude Meter
In addition to full WAN analysis, the Agilent Advisor E1/T1 and E3/T3 interfaces
have a built-in pulse amplitude signal strength power meter that allows users to
check pulse amplitude levels with a resolution of +/- 1 dBm. The dynamic range
is between +6 dBmV and 40 dBmV.
Bit Error Ratio Testing (BERT)
Often problems on the network can be attributed to the transmission medium.
The Agilent Advisor has a powerful, built-in bit error ratio test capability. For a
complete description of this functionality, please refer to the section on BERT
later in this document.
Frame Relay
(continued)