Extron Electronics IPL T SFI244 User Manual
Page 47

Command/r
esponse table for SIS commands (continued)
Command
ASCII (T
elnet)
URL Encoded (W
eb)
Response
Read string fr
om event
memory
27
E
X3%
,
X3^
,
X3&
,
X4$
FE
}
W
X3%
%2C
X3^
%2C
X3&
%2C
X4$
FE
|
string
]
W
rite string to event
memory
24 27
E
string
*
X3%
,
X3^
,
X3&
FE
}
W
string
%2A
X3%
%2C
X3^
%2C
X3&
FE
|
Evt
X3%
,
X3^
,
X3&
string
]
Start events
24 27
E
1AE
}
W1AE
|
Ego
]
Stop events
24 27
E
0AE
}
W0AE
|
Est
]
Read number of events
running
E
AE
}
W
AE
|
Enm#####
]
Reset (zap)/erase commands
Erase user
-supplied W
eb page
and files
24 28
E
filename
EF
}
W
filename
EF
|
Del•
filename
]
Erase flash memory
24
E
ZFFF
}
WZFFF
|
Zpf
]
Reset all device settings to
factory
24
E
ZXXX
}
WZXXX
|
Zpx
]
Absolute system r
eset
24
E
ZQQQ
}
WZQQQ
|
Zpq
]
NOTE:
Reset all settings/memories. The ZQQQ command r
esets everything (all settings, adjustments, the IP addr
ess, and subnet mask) to the factory default values. Files
in flash memory ar
e also erased by this command. The firmwar
e version does not change. The IP addr
ess is r
eset to 192.168.254.254, the subnet mask is r
eset to
255.255.0.0.
NOTE:
X3%
= Event number: range = 0-99 (max)
X3^
= Event buf
fer: 0 = r
eceive; 1 = user (absolute); 2 = user (r
elative); 3 = NVRAM
X3&
= Event buf
fer of
fset: range = 0-MaxBuf
ferSize
X4$
= Number of bytes to r
ead
IPL T SFI244 • Communication and Control
41