beautypg.com

Extron Electronics IPL T SFI244 User Manual

Page 22

background image

4.

Access the command prompt, then execute the

arp -s command.

Enter the desired new IP address and the MAC address (the MAC address is located
on the rear panel’s upper right corner) for the IPL T SFI244 unit. For example:

arp -s 10.13.170.15 00-05-A6-00-0A-90

Figure 13.

Executing the ARP Command

5.

Execute a ping command by typing your new IP address in the command prompt. For
example:
ping 10.13.170.15

After issuing this command, the unit changes to the new address and starts
responding to the ping requests, as shown below. The IPL T SFI244 unit’s IP address
should now be updated to the new address, and then you can reconnect using either
Telnet or the Web to verify that the update was successful.

Figure 14.

Unit Response to a Ping Request

6.

After verifying that the change was successful, issue the

arp -d command in the

command prompt. For example:
arp -d 10.13.170.15 removes 10.13.170.15 from the arp table

or

arp -d* removes all static IP addresses from the arp table.

IPL T SFI244 • Connection and Configuration

16