Command/r esponse table for sis commands – Extron Electronics IPL T SFI244 User Manual

Page 42

background image

Command

ASCII (T

elnet)

URL Encoded (W

eb)

Response

Bidir

ectional serial data port

Send data string

E 

X!

*

X1&

*

X2)

*

X2!

RS

}X@

W

X! 

%2A

 X1& 

%2A

 X2) 

%2A

 X2! 

RS|

 X@

response fr

om command

]

Configur

e parameters

24

E 

X!

*

X2%

,

X2^

,

X2&

,

X2*

CP

}

W

X! 

%2A

 X2% 

%2C

 X2^ 

%2C

 X2&

%2C

 X2*

CP

|

Cpn

X!

•Ccp

X2%

,

X2^

,

X2&

,

X2*]

V

iew parameters

E 

X!

CP

}

W

X!

CP

|

X2%

,

X2^

,

X2&

,

X2*]

Configur

e mode

24

E 

X!

*

X2(

CY

}

W

X! 

%2A

 X2(

CY

|

Cpn

 X!

•Cty

 X2)]

Configur

e flow contr

ol

24

E 

X!

*

X3)

,

X3!

CF

}

W

X!

%2A

X3)

%2C

X3!

CF

|

Cpn

 X!

•Cfl

 X3)

,

X3!

V

iew flow contr

ol

E 

X!

CF

}

E 

X!

CF

|

X3)

,

X3!]

Configur

e r

eceive timeout

24

E 

X!

*

X1&

*

X2)

*

X2#

CE

}

W

X! 

%2A

 X1& 

%2A

 X2) 

%2A

 X2#

CE

|

Cpn

 X!

•Cce

X1&

,

X2)

,

X2#]

V

iew r

eceive timeout

E 

X!

CE

}

W

X!

CE

|

X1&

,

X2)

,

X2#]

Configur

e r

edir

ect mode

24

E 

X!

*

X5)

*

X5#

CD

}

W

X! 

%2A

 X5) 

%2A

 X5#

CD

|

Cpn

 X!

•Ccd

X5)

,

X5#]

V

iew r

edir

ect mode

E 

X!

CD

}

W

X!

CD

|

X5)

,

X5#]

Terminate r

edir

ect mode

24

E 

X!

*0CD

}

W

X! 

%2A

0CD

|

Cpn

 X!

•Ccd0,0

Flex I/O data port

Set I/O mode (modes 0-5)

X!

*

X4) 

[

X! 

%2A

 X4) 

%5B

Cpn

 X!

•Iom

 X4)]

Set I/O mode

(modes 6-7)

X!

*

X4)

*

X5%

*

X5^ 

[

X! 

%2A

 X4) 

%2A

 X5% 

%2A

 X5^ 

%5B

Cpn

 X!

•Iom

 X4)

,

X5%

,

X5^

]

V

iew I/O mode

X! 

[

X!

%5B

X4)

,

X5%

,

X5^]

NOTE:

X!

= Specific port number (01-99)

X@

= Command data section

X1&

= T

ime to wait for characters coming into serial port befor

e terminating (default = 10 = 100 milliseconds, max = 32767)

X2)

= T

ime to wait between characters coming into serial port befor

e terminating (default = 2 = 20 milliseconds, max = 32767)

X2!

= Parameter to set either Length of message to r

eceive or Delimiter value.

X2#

= Priority status for r

eceive timeoutt: 0 = priority set to Send Data String command parameters, 1 = priority set to configur

e r

eceived timeout command

parameters

X2%

= Baud rate: 300, 600, 1200, 1800, 2400, 3600, 4800, 7200, 9600, 14400, 19200, 28800, 38400, 57600, 115200

X2^

= Parity:

O

dd,

Even,

N

one,

M

ark,

Space (only first letter is r

equir

ed)

X2&

= Data bits: 7, 8

X2*

= Stop bits: 1, 2

X2(

= Port type: RS-232, RS-422, RS-485 (or 0,1, or 2, r

espectively). (

X2(

= 0 for the SFI244)

X3)

= Flow Contr

ol:

H

ar

dwar

e,

Softwar

e,

N

one (only first letter is r

equir

ed)

X3!

= Data pacing: 0000-1000 (default = 0 milliseconds)

X4)

= I/O mode:

0 = input; 1 = output; 2 = input plus pull-up r

esistor; 3 = output plus pull-up r

esistor; 4 = analog in; 5 = analog in w/pull-up; 6 = adjust in

(r

equir

es

X5%

&

X5^

thr

esholds); 7 = adjust in w/pull-up (r

equir

es

 X5%

&

X5^

thr

esholds).

X5%

&

X5^

thr

esholds ar

e not r

equir

ed for modes 0-5.

X5)

= Redir

ect: 0 = no r

edir

ect; 1-n= r

edir

ect serial port fr

om the specified port to allow for a transpar

ent pass-thr

ough mode

X5#

= T

imeout for data pass-thr

ough mode, after which event data can be inserted into the transpar

ent buf

fer

X5%

= Upper transition thr

eshold (0 detection = of

f) for digital inputs

X5^

= Lower transition thr

eshold (1 detection = on) for digital inputs

Command/r

esponse table for SIS commands

IPL T SFI244 • Communication and Control

36