beautypg.com

Extron Electronics IPL T SFI244 User Manual

Page 41

background image

X6#

= Pulse time in 20 milliseconds per count. If parameter is missing or = 0, pulse length = default

(25 counts = 500 milliseconds), max (65536 counts)

X6$

= Broadcast repetition rate in seconds (0-256. 0 = disable)

Copyright information

]

(c) COPYRIGHT 2009, EXTRON ELECTRONICS IPL T SFI244, Vx.xx, 60-544-86

]

Thurs, 28 Jan 2010 16:29:10

The copyright message is displayed upon connecting to IP Link product via TCP/IP or
Telnet. Vx.xx is the firmware version number. The unit’s part number, the current date,
and time are displayed as well. This is followed by a password prompt.

Password information

The “

]

Password:” prompt requires a password (administrator level or user level) followed

by a carriage return. The prompt is repeated if the correct password is not entered.

If the correct password is entered, the unit responds with “

]

Login Administrator

]

” or

]

Login User

]

”, depending on the password entered. If passwords are the same for

both administrator and user, the unit defaults to administrator privileges.

Error responses

When the IPL T SFI244 receives a valid command, it executes the command and sends a
response to the host device. If the unit is unable to execute the command because the
command contains invalid parameters, it returns an error response to the host.

E10 — Invalid command
E12 — Invalid port number
E13 — Invalid parameter
E14 — Not valid for this configuration
E17 — System timed out
E22 — Busy
E24 — Privilege violation
E25 — Device not present
E26 — Maximum number of connections exceeded
E27 — Invalid event number
E28 — Bad filename/file not found
E31 — Attempt to break port pass-through when not set (A user or software attempted to
disable the port redirect feature when it wasn’t already set or active.)

References to errors (at command descriptions on the following

pages)

10

= Commands that give E10 (invalid command).

24

= Commands that give E24 (privilege violation) if not administrator level.

27

= Commands that may give E27 (invalid event number).

28

= Commands that may give E28 (file not found).

IPL T SFI244 • Communication and Control

35