Extron Electronics IPL T SFI244 User Manual
Page 43

Command/r
esponse table for SIS commands (continued)
Command
ASCII (T
elnet)
URL Encoded (W
eb)
Response
Pulse I/O state
10 14
X!
*3*
X6#
]
X!
%2A
3
%2A
X6#
%5D
Cpn
X!
•Sio
X%]
Toggle I/O state
10 14
X!
*2
]
X!
%2A
2
%5D
Cpn
X!
•Sio
X%]
Set I/O state ON
X!
*1
]
X!
%2A
1
%5D
Cpn
X!
•Sio1
]
Set I/O state OFF
X!
*0
]
X!
%2A
0
%5D
Cpn
X!
•Sio0
]
V
iew I/O state
X!
]
X!
%5D
X4#]
IR/serial data port
Send IR command
28
E
X!
X5&
,
X5*
,
X5(
IR
}
W
X!
%2C
X5&
%2C
X5*
%2C
X5(
IR
|
Irs
X!
,
X5&
,
X5*
,
X5(]
Get IR command info
28
E
X5&
,
X5*
,IR
}
{description text}
]
Firmwar
e version/part number/information
Query firmwar
e version
Q
Q
X1!]
Query verbose version
information
0Q
0Q
sum of r
esponses fr
om 2Q-3Q-4Q
]
Query firmwar
e version
1Q
1Q
X1!]
Query bootstrap version
2Q
2Q
X1!]
Query factory firmwar
e
version
3Q
3Q
X1!
(plus web ver
.-desc-UL date/time)
]
Query updated firmwar
e
version
4Q
4Q
X1!
(plus web ver
.-desc-UL date/time)
]
NOTE:
An asterisk (*) placed after the version number indicates which version is curr
ently running. A question mark (?) indicates that only the factory firmwar
e version
is loaded. A car
et (^) after the version number indicates the firmwar
e version that should be running, but a Mode 1 r
eset was executed. The default factory
firmwar
e version is loaded. An exclamation point (!) after the version number indicates corrupted firmwar
e.)
Request part number
N
N
60-xxx-yy
]
Request model name
1I
1I
IPL T SFI244
]
Request model description
2I
2I
Two Bi-Dir
ectional Serial Ports [RS232], Four Flex I/O,
Four IR Ports
]
Request system memory
usage
3I
3I
# Bytes/Kbytes used out of # Kbytes
]
Request user memory usage
4I
4I
# Bytes/Kbytes used out of # Kbytes
]
NOTE:
X!
= Specific port number (01-99)
X%
= On/of
f status: 0 = of
f/disable; 1 = on/enable
X1!
= Unit firmwar
e version
X4#
= 0 = of
f; 1 = on; value = 0-4095, based on a 12-bit A to D
X5&
= IR playback file number (0-99)
X5*
= IR function number
X5(
= IR playback mode: 0 = play once; 1 = play continuously (send IR command again with mode = 0 to stop mode 1 playback)
X6#
= Pulse time in 20 milliseconds per count
IPL T SFI244 • Communication and Control
37