Command
ASCII Command
(Host to Tuner)
Response
(Tuner to Host)
Additional Description
IP Setup Commands
Set unit name
EX5@
CN
}
Ipn•
X5@]
Set AVT unit name
X5@
.
X5@
can
be up to 24 characters consisting
of A through Z, a through z,
0 through 9, and hyphen (-).
The first letter must be
alphabetical; the last one must
not be a hyphen.
View unit name
E
CN
}
X5@]
Reset unit name to factory
default
24
E
•CN
}
Ipn•
X8%]
Reset the AVT name to its
factory default name
X8%
.
X8%
consists of the model name
and the last three pairs of the
MAC address.
Example:
E
•CN
}
Ipn•AVT-200-HD-05-62-3D
Set time and date
24
EX5#
CT
}
Ipt
X5#]
X5#
is the local date and time
format. The set format is MM/
DD/YY-HH:MM:SS. (The hours,
minutes, and seconds can also
be separated by periods.)
Examples:
11/13/06-10:54:00 or
11/13/06-10.54.00
View time and date
E
CT
}
X5#]
Set GMT offset
24
EX4#
CZ
}
Ipz
X4#]
Set the Greenwich Mean Time
(GMT) offset value (
X4#
) for
the AVT location. GMT offset
(-12.00 through +14.00)
represents the time difference
in hours and minutes (± hh:mm
relative to Greenwich, England).
The plus sign and leading zero
are optional.
X4#
is in the format hh:mm.
Example: 5:30 or 5.30 =
+05:30
NOTE: In the command, the divider between hours and minutes can be a colon or a period. In the response, it is a colon.
Example:
E
8.0CZ
}
Ipz+08:00
]
View GMT offset
E
CZ
}
X4#]
Set Daylight Saving Time
24
EX7#
CX
}
Ipx
X7#]
Set daylight saving time
X7#
:
0 = off or ignore
1 = USA (Begins second Sunday
in March and ends first
Sunday in November.)
2 = Europe (Begins last
Sunday in March and
ends last Sunday in
October.)
3 = Brazil (Begins third Sunday
in October and ends third
Sunday in February.)
View Daylight Saving
Time
E
CX
}
X7#]