Gas sampling and gas conditioning technology

2-1.1.4-ME

13.4.2

VERSION SP2000-H320/S1 WITH ELECTRONIC TEMPERATURE CONTROLLER

The gas sample probe is supplied either as unit with a fixed and electrically connected temperature
controller, or the temperature controller is attached as separate unit for external mounting. Then, the
electrical connection is to be made as follows:

Remove the lid of the connection box on the gas sample probe. Inside the lid, you will find the

terminal connection plan.

Insert the mains cable (min. 3 x 1,5 mm

2

, terminal range 6

– 12mm) through the medium cable

gland of the gas sample probe and connect it to the appropriate terminals.

Insert the temperature sensor cable into the right cable gland of the gas sample probe and

connect it to the appropriate terminals.

Screw the lid on again.

Figure 10 Electrical connection SP2000-H320/S1 with electronic controller eg. type 703G

N O T E !

As sensor line an equalization line has to be provided. The cor-
responding thermo equalization terminals are provided inside
the connection box.