M&C TechGroup SP35-H... for gas sample probe SP2000-H... Data sheet User Manual

Electrically heated sample probe tube series sp, Special features, Application

background image

M&C TechGroup Germany GmbH • Rehhecke 79 • 40885 Ratingen • Germany

[email protected] • www.mc-techgroup.com • Fon +49 2102 935-0 • Fax +49 2102 935-111

2.15

Embracing Challenge

ƒ

ƒ

Completely heated sample tube

ƒ

ƒ

Different lengths

ƒ

ƒ

Unheated pre-filters or extensions pos-
sible

ƒ

ƒ

Simultaneously heated pre-filter pos-
sible

ƒ

ƒ

Easy mounting

ƒ

ƒ

Two temperature sensor versions

Special Features

Electrically heated sample probe tube
series SP®

Version SP30-H..., SP30-H1.1-V, SP35-H...
for gas sample probe SP2000-H...

SP30-H1.1

Application

The electrically heated M&C sample probe

tube SP30/35-H... is used in extractive sam-

pling systems to avoid cooling and conden-

sation of the sample in the insitu tube from

the sample point to the heated sample probe

SP2000-H.
To avoid a premature demage by cooling and

condenstaion in dust loaded processes, we

recommend a heated tube type SP30-H1.1-V,

including an insitu pre-filter V20-2/30, heated

up with the tube.

Description

The electrically heated M&C sample tube

SP30-H... is available in 0,6 m, 1,0 m, 1,5 m

and 2,0 m length and the SP35-H... in 0,175 m

length. The standard lengths for the pre-filter

version SP30-H1.1-V are 0,6 m and 1,0 m. The

tube version SP30-H..., SP35-H... has an inter-

nal diameter of 22 mm. The internal diameter

of the version SP30-H1.1-V is reduced to 6

mm to optimise the tube dead volume.
With a mounting flange with 4 welded screws

the heated sample tube SP30-H.../-V, SP35-H..

can be easily fixed both to the flange at the

sample point and the probe head SP2000-H.

The heated sample tube SP30-H.../SP35-H... is

equipped with a G3/4»i thread connector at

the tube end. This enables fixing a standard

non heated sample tube or pre-filter to the

heated insitu tube.
The electrical cartridge heater is located inside

a double tube system, completely separated

from the process. At the version SP30-H1.1-V

the included large pre-filter V20-2/30 is heat-

ed up with the sample tube. The temperature

of the heated tube has to be adjusted in

relation to the process temperature and cor-

responding to the max. admissable sampling

temperature.
Depending on the operating temperature

the sample tubes are equipped either with a

thermocouple (max. 320 °C) or a PT100 tem-

perature sensor (max. 200 °C).