M&C TechGroup CSS-V2 Data sheet User Manual

Gas conditioning unit series css, Special features, Application

background image

M&C TechGroup Germany GmbH • Rehhecke 79 • 40885 Ratingen • Germany

[email protected] • www.mc-techgroup.com • Fon +49 2102 935-0 • Fax +49 2102 935-111

14.1

Embracing Challenge

ƒ

ƒ

Compact high-performance construc-
tion with compressor cooler

ƒ

ƒ

Individually configurable

ƒ

ƒ

Completely pre-installed

ƒ

ƒ

One or two gas streams

ƒ

ƒ

19”- or wall mounting housing

ƒ

ƒ

Low maintenance and self-monitoring

ƒ

ƒ

Outlet dew point adjustable from +2 °C
to +7 °C

ƒ

ƒ

Dew point stability ± 0,1°C

ƒ

ƒ

Operational in 10 minutes

ƒ

ƒ

Light weight

ƒ

ƒ

Optimum reliability

Special Features

Gas Conditioning Unit series CSS®

Version CSS-V1 for max. 1 x 250Nl/h gas flow rate,
Version CSS-V2 for max. 2 x 150Nl/h gas flow rate,
for 19”- or wall mounting

CSS-V2

Application

The units CSS-V.. provide a complete pre-

installed compact high-performance sample

gas conditioning for continuous use. Due to a

big variety of additional options the gas con-

ditioning units excellently can be adapted to

the most diverse requirements of gas analysis

technique.
Its compact construction only takes up little
space. The CSS-V units are ready for use in a
few minutes. This makes time-consumingpro-

curement of individual components and
assembly superfluous.

Description

All components of the gas conditioning unit

are mounted in a compact sheet steel case.
Filter, flowmeter and peristaltic pump are

placed into the front panel and thus assure a

very easy maintenance.
The compressor gas cooler is equipped with

one or two heat exchangers of Duran glass,

stainless steel SS316Ti or PVDF.
The fine filter FPF-2-0,3GF (0,3µm filter fine-

ness) installed in front of the sample gas

pump N3/5/9 KPE ensures the necessary

removal of solid particles. The condition of

the filter element is visible from outside.
The downstream installed sample gas pump

N3/5/9 KPE is available with 3 pump capaci-

ties.
The flow meter FM40 with corresponding

measuring range installed in the sample gas

outlet can be equipped with a flow alarm

sensor FA-20mo and the adequate electronic.
The unit contains a temperature alarm con-

tact that is activated in case the temperature

differs more than +/-3 °C from the set value (+

5°C) adjusted at the factory and switches off

the sample gas pump if existing.
The condensate occurred is removed con-

tinuously via the peristaltic pump type SR25.2.

The ventilation grids in the sidewalls ensure

that the equipment is sufficiently ventilated.
A liquid alarm sensor is integrated in the filter

FPF-2-0,3GF to protect the downstream ana-

lysers against liquid irruptions and to increase

the operating safety of the whole system. Via

one or two potential free contacts for the

summery alarm (cooler temperature, gas flow,

liquid) an alarm is indicated and the sample

gas pump, if existing, is switched off.