M&C TechGroup FPF+ Data sheet User Manual

Front panel mounting fine filter series fp, Version fpf, Special features

background image

M&C TechGroup Germany GmbH • Rehhecke 79 • 40885 Ratingen • Germany

[email protected] • www.mc-techgroup.com • Fon +49 2102 935-0 • Fax +49 2102 935-111

7.2a

Embracing Challenge

ƒ

ƒ

Corrosion resistant

ƒ

ƒ

Large filter elements

ƒ

ƒ

Big variety of filter element materials
with different porosities possible

ƒ

ƒ

Compact liquid alarm sensor as option

ƒ

ƒ

Low stagnant space

ƒ

ƒ

Simple construction

ƒ

ƒ

Simple assembly

ƒ

ƒ

Easy change of filter element

ƒ

ƒ

Universal usability

Special Features

Front panel mounting fine filter
series FP®

Version FPF+

FPF+ 3SS

Application

The M&C front panel mounting extra-fine

filters reliably separate solids, in particular very

fine particles, occurring in analysis techniques

in gas filtration, using very fine, deep-acting

filter elements. The large filter surface of the

cylindrical filter element with 75mm length

guarantees reliable extra-fine filtration and a

long service life with low pressure drop.
The optional integrable liquid alarm sensor

LA3 is used in gas sample conditioning sys-

tems for monitoring gas cooling and conden-

sate drain-off devices in order to provide pro-

tection for downstream analysis instruments.

This simple monitoring device reliably signals

the penetration of condensate in the event of

cooling or condensate drain-off equipment

being defective and thus avoids expensive

down times as well as high repair costs for

analysis instruments.
In the event of alarm, the power for the

sample gas pump or a solenoid valve is to be

switched off in the gas sample conditioning

system.

Description

Special features of the M&C FPF+ front panel

mounting filter are large filter surface, big

variety of different filter element materials

and porosities, integrable liquid alarm sensor,

low stagnant space, simple construction and

assembly as well as universal usability.
The condition of the filter can be seen imme-

diately from outside through the filter glass

without opening the filter fitting. No tools

are needed for changing the filter element;

here, the optimum positioning of the seal-

ing O-ring always guarantees reliable sealing

between filter glass and filter body.
The gas connections are located at the back

in the filter body. If no liquid sensor is used,

the inlet of the measuring gas can be turned

by 90° steps at the front ring attachment so

that a flexible adjustment to local conditions

is possible when assembling.

Corresponding tube connectors can be

optionally supplied (see data sheet 11.6).
The optional integrable liquid sensor LA3

works on the principle of electrical conduc-

tivity from 50 µS/cm conductance. In order

to avoid electrolytic effects on the sensor

surface, the sensors are powered with alter-

nating current.
The liquid sensor is located in the sample gas

inlet that any droplets of liquid in the sample

gas are attracted under gravity to the sensor

surface and even the smallest liquid droplets

trigger a sure and rapid alarm.
The required electronic controller LA-1.. is

available in various versions and is described

in the separate data sheet 8.2.