M&C TechGroup CG Series Data sheet User Manual
Gasconverterseriescg, Specialfeatures, Application
M&C TechGroup Germany GmbH • Rehhecke 79 • 40885 Ratingen • Germany
[email protected] • www.mc-techgroup.com • Fon +49 2102 935-0 • Fax +49 2102 935-111
12.1
Embracing Challenge
Highflowcapacity,longoperatingtime,
highconversionefficiency
Catalystcartridgeeasytochangewith-
outanytools
Operatingtemperatureupto680°C
Versionwithnonheatedgasinletand
outletbuiltinacompact19”-rackhous-
ing
Versionwithheatedgasinletandoutlet
builtinacompactwallmountinghous-
ing
Safehandlingandeasyservicing
Bypasssolenoidvalves
SpecialFeatures
GasConverterSeriesCG®
Version CG-2 and CG-2M, gas inlet and outlet non heated,
in a 19”-rack-housing
Version CG-2H-W and CG-2MH-W, gas inlet and outlet
heated, in a wall mounting housing
CG-2
Application
In many countries, clean-air regulations
require a continuous measurement of nitro-
gen oxides NO
X
, as the sum of nitrogen
dioxide NO
2
and nitrogen monoxide NO, for
combustion processes as soon as the part of
NO
2
exceeds 5% of the total NO
X
emission.
Due to the conversion to NO the use of a
standard NO-analyser is possible.
Description
The conversion of NO
2
into NO depends on
a catalytic reaction. Therefore, the sample
gas passes the M&C gas converter type CG ...
via a catalyst cartridge type C, filled up with
molybdenum-coated carbon. This conversion
allows an indirect nitrogen oxide measure-
ment with all NO selctive usual commercial
measuring instruments. For a ratio of NO
2
/
NO >50% or a NO
2
concentration >200ppm a
filling of metal type SS is available.
The compact 19“-design of the M&C gas
converters CG-2 and CG-2M guarantees com-
patible and safe handling as well as easy serv-
icing. The 19“-rack can optional be equipped
with a wall mounting bracket.
The M&C gas converters CG-2H-W and
CG-2MH-W are built in a wall mounting hous-
ing.
The cylindric, ready for use prepared cartridge
is built into a heat-insulated tube furnace
easily accessible at the front or top panel of
the converter. By turning the special adapter
handle the cartridge can be changed without
any tools.
The temperature of the cartridge can be
adjusted between +50°C and 680°C at a PID
temperature controller on the front panel of
the converter. A status alarm contact for high
and low temperature alarm is available.
Using different catalysts at specific proc-
ess temperatures, the M&C gas converter
CG ... is suitable for various applications.
The converter is available in four versions:
CG-2 and CG-2M for „cold gas“ conversion
and CG-2H-W respectively CG-2MH-W with
heated gas inlet, outlet and a second heating
circuit for „hot gas“ conversion.
For test purposes the converter cartridge
can be bypassed via 3/2-way solenoid valves
out of PVDF in version CG-2M and out of
stainless steel in version CG-2MH-W. Version
CG-2M is equipped with two and the version
CG-2MH-W with one solenoid valve. An exter-
nal control is possible.
The versions CG-2 and CG-2H are working
without bypass valves.
We like to inform you about a suitable gas
conditioning system to be connected up- or
downstream the converter !
Technical specifications and illustrations are without
obligation, subject to modifications. 07.00/12.06