Example, 5 gpis out advance and duration, Gpi out advance – EVS MulticamLSM Version 10.01 - October 2009 Configuration Manual User Manual
Page 84: Gpi pulse duration, Tion, 5 gpi, Dvance and, Uration
EVS Multicam Version 10.01 – Configuration Manual
EVS Broadcast Equipment SA – October 2009
Issue 10.01.I
77
Example
Users can select all types of GPIs. The behaviour varies accordingly:
Before
the
IN
On Replace
IN
Between IN
and OUT
On Replace
OUT
After the
OUT
High Low
High
High
Low
Low
Low High Low
Low
High
High
High
Pulse
Low
High Pulse
Low
High Pulse
Low
Low
Pulse
High
Low Pulse
High
Low Pulse
High
3.19.5 GPI
S
OUT
A
DVANCE AND
D
URATION
GPI OUT Settings p.8.6
GPI# Advance Duration
1 [F1]Disable [F5]01s00fr
2 [F2]Disable [F6]01s00fr
3 [F3]Disable [F7]01s00fr
4 [F4]Disable [F8]01s00fr
[Menu]Quit [Clr+F_]Dft [F9]PgUp [F0]PgDn
GPI OUT Settings p.8.7
GPI# Advance Duration
5 [F1]Disable [F5]01s00fr
6 [F2]Disable [F6]01s00fr
7 [F3]Disable [F7]01s00fr
8 [F4]Disable [F8]01s00fr
[Menu]Quit [Clr+F_]Dft [F9]PgUp [F0]PgDn
GPI OUT Advance
Possible values: Disable (default) / 00s01fr to 02s00fr
Possible values: up to 2 seconds, frame by frame (like GPI delay)
When a GPI out advance setting is set (for instance 2 fr.), the GPI OUT is sent 2
frames in advance.
GPI Pulse Duration
Possible values: Disable / 00s01fr to 02s00fr. Default: 01s00fr.
Set the default duration for pulse GPIs.