Initial setup, Nitial, Etup – AASTRA SIP-DECT (Release 2.1)- OM System Manual - Installation, Administration and Maintenance EN User Manual
Page 17: 2 initial setup
SIP – DECT OM System Manual Release 2.1
2 Getting Started
depl-1230/1.3
Page: 17 (196)
•
via the DHCP request (see chapter 7.5.3.1),
•
within the static local configuration of an RFP (see chapter 7.6),
•
within the RFP configuration file of a PC-based OMM (see chapter 7.7).
The RFP which has the same IP address as the dedicated OMM IP address will be the RFP
which the OMM application runs on.If two OMM IP adresses are configured, the OMM
application is started on both dedicated RFPs. One OMM becomes the active OMM and the
other the standby OMM. For more details about the standby feature, see chapter 7.11.
2.2
Initial Setup
After bringing up the DHCP/TFTP server and starting the RFPs, you can start a web browser
and call up the web-based user interface of the OMM. Alternatively, the Java-based
OpenMobility Manager (“omp.jar”) may be used. The following step-by-step description
emphasizes on the OMM’s web console.
1 Start a web browser and navigate to the IP address that you have configured for the OMM
in the DHCP option 43. This will display the OMM’s login page.
Note: The browser’s communication with the OMM’s web console is secured by the
HTTPS protocol. However, since you cannot validate a numeric intranet address
with a certifacte chain, you need to ignore / overwrite the web browser’s warning
about invalid certificates.
2 Enter “omm” in the
User name
input field. Also enter “omm” in the
Password
input field.
Click the
OK
button to log in. In the factory default configuration, the OMM now displays
the
Info: End-user license agreement
page. Read the agreement and confirm by
clicking the
Accept
button.
OMM web console, login with “omm” / “omm”
3 On the next two pages that are displayed automatically, you need to enter new passwords
for two administrative user accounts. The first account is the “omm” user that can change
the configuration. The second account can be used to call up the OMM’s command line
shell via SSH. Enter passwords that contain at least lower case letters, capital letters, and
digits. After changing the passwords, the web console shows the
Status
page.
4 Navigate to the
System: System settings
page. Change the
PARK
setting to the PARK
code that is printed on the installation CD-ROM. Also change the
Regulatory domain
to
match your region. Confirm with
OK
.