6 OM Management Portal (OMP)
depl-1230/1.3
Page: 107 (196)
6.8.4
PP Detail Panel
The PP detail panel is used for configuration/showing of PP settings and creation of new PP
datasets.
To call up the PP detail panel
•
choose one of the commands in the task bar on the right of the
Portable parts
panel
(
Create
,
Configure
, or
Show details
)
or
•
select the appropriate PP in the PP table and double-click the entry.
The PP detail panel contains the different parameter groups sorted in tabs. Which tabs are
displayed depends on the current mode and from which panel the PP detail panel was called
up:
•
Overview
panel (configuration and monitor mode): The PP detail panel contains all tabs
listed below.
•
User
panel (configuration mode): The PP detail panel contains all tabs but not
DECT
.
•
Device
panel (configuration mode): The PP detail panel contains only
DECT
.
“General” tab
This tab enables to configure the general settings for the PP dataset.
•
Name
: represents the handset user name with up to 20 characters
•
Number
: the handset telephone number with up to 31 characters (1234567890*#azAz+-
_.!$%&/()=?$&). Please be aware that only “*”,”#” and “0” to “9” can be dialled with a
handset..
•
Description 1
and
Description 2
: free text comments with up to16 characters each.
•
Additional ID
: The additional ID can be used as a mean for data search within wildcard
subscription (because of the IPEI is not configured which selects the data otherwise).
Note: The authentication code and additional ID can only be changed if the PP is not
subscribed.
•
PIN
: a user PIN to be entered during user login.
“SIP” tab
This tab enables to configure the SIP authentication for the PP dataset.