Toshiba PORTEGE M400 User Manual
Page 86
2 Troubleshooting
2.6 2.5” HDD Troubleshooting
2-38
[CONFIDENTIAL]
PORTEGE M400 Maintenance Manual (960-541)
Procedure 4
Diagnostic Test Program Execution Check
The HDD test program is stored in the Diagnostics Disk. Perform all of the HDD tests in the
Hard Disk Drive Test. Refer to Chapter 3, Tests and Diagnostics, for more information about
the HDD test program.
If an error is detected during the HDD test, an error code and status will be displayed. The
error codes and statuses are described in Table 2-5. If an error code is not displayed but the
problem still exists, go to Procedure 5.
Table 2-5 2.5” HDD error code and status
Code Status
01h Bad
command
02h
Address mark not found
04h
Record not found
05h
HDC not reset
07h
Drive not initialized
08h
HDC overrun error (DRQ)
09h
DMA boundary error
0Ah
Bad sector error
0Bh
Bad track error
10h ECC
error
11h ECC
recover
enable
20h HDC
error
40h Seek
error
80h
Time out error
AAh
Drive not ready
BBh Undefined
error
CCh Write
fault
E0h Status
error
EEh
Access time out error
DAh No
HDD