beautypg.com

Toshiba PORTEGE M400 User Manual

Page 57

background image

2.3 Power Supply Troubleshooting

2 Troubleshooting

Procedure 2

Error Code Check

If the power supply microprocessor detects a malfunction, the DC IN icon blinks orange. The
blink pattern indicates an error as shown below.

‰ Start

Off

for

2

seconds

‰ Error code (8 bit)

“1”

On

for

one

second

“0”

On

for

half

second

Interval between data bits

On

for

half

second

The error code begins with LSB (Least Significant bit)
Example: Error code 11h (Error codes are given in hexadecimal format.)

Check 1

Convert the DC IN icon blink pattern into the hexadecimal error code and
compare it to the tables below. Then go to Check 2.

‰ Error code

Error code

Power supply of error detected

1*h AC

Adapter

2*h

1

st

battery

3*h 2

nd

battery

4*h

S3V output (P60)

5*h

E5V output (P61)

6*h

E3V output (P62)

7*h

1R5-E1V output (P63_CH0)

8*h

1R-8-B1V output (P64_CH0)

9*h

PPV output (P65_CH0)

A*h

PTV output (P66_CH0)

B*h

1R5-E1V output (P63_CH1)

C*h

1R8-B1V output (P64_CH1)

D*h

PPV output (P65_CH1)

E*h

PTV output (P66_CH1)

PORTEGE M400 Maintenance Manual (960-541)

[CONFIDENTIAL]

2-9