Installing the lcd unit/fl inverter – Toshiba PORTEGE M400 User Manual
Page 305
4.25 LCD unit/FL inverter
4 Replacement Procedures
PORTEGE M400 Maintenance Manual (960-541)
[CONFIDENTIAL]
4-67
Installing the LCD unit/FL inverter
The following describes the procedure for installing the LCD unit/FL inverter. (See Figure 4-
43 to 4-46.)
1. Stand the LCD unit on the display cover and connect the digitizer cable and LCD
cable on the back of the LCD unit.
2. Stick two glass tapes on each connector.
3. Install the LCD unit to the display cover and secure it with the following screws.
• M2.0×4.0B BIND
screw
×4
4. Stick the FL inverter to the slot.
CAUTION: The FL inverter is stuck to the cover with a double-sided tape. Once
removing a FL inverter, be sure not reuse it. Use new one.
5. Stick one insulator on the FL inverter and insert one insulator under the LCD unit
6. Connect two cables to the connectors on the FL inverter.
7. Install the LCD mask to the display cover while securing the latches.
NOTE: When installing the LCD mask, wipe the LCD with a soft cloth and make the back
of the LCD mask clean with an ionizer.
8. Secure the LCD mask with the following screws and stick the mask seals (7 points).
• M2.5×6.0B
FLAT HEAD screw
×6
• M2.0×6.0S
BIND
screw
Ч1