beautypg.com

Toshiba PORTEGE M400 User Manual

Page 325

background image

4.31 Fluorescent lamp

4 Replacement Procedure

Removing the cell with PCB

1. Remove the cell with PCB from the backlight unit as shown bellow.

2. Completely remove the double-sided tape remaining on the reverse side of the cell.

CAUTION: 1. A portion of the upper side of cell is adhered to the frame with the

double-sided tape. Remove the cell gently, taking care not to damage it.
2. Do not remove the ray-shield tape on the upper, lower, right and left of
face and back of cell.
3. Be careful not to damage the FPC.

Figure 4-58 Replacing 12.1 Inch TMD fluorescent lamp (6)

PORTEGE M400 Maintenance Manual (960-541)

[CONFIDENTIAL]

4-87