beautypg.com

31 fluorescent lamp – Toshiba PORTEGE M400 User Manual

Page 318

background image

4 Replacement Procedure

4.31 Fluorescent lamp

4-80

[CONFIDENTIAL]

PORTEGE M400 Maintenance Manual (960-541)

4

4.31 Fluorescent lamp

This system uses LCD modules from the following suppliers. The procedure for replacing
the fluorescent lamp is different for each LCD module. Refer to the appropriate procedure.

Type Part

No.

Supplier Section

12.1-inch (XGA)

G33C00037110 TMD

4.31.1

12.1-inch (SXGA+)

G33C00019210 TMD

4.31.1

NOTE: - When working with a LCD module, always use a flat, grounded table.

- Handle the backlight unit in the environment without dust, such as on the clean

bench. Keep the worktable free from any screws or other material that may
scratch the LCD surface.

- Use an anti-static or protective sheet.

- When replacing the FL unit, cover with a finger protector or similar to prevent

soiling or scratching the LCD panel.

- Be careful when handling the lamp. Excessive force may break the lamp.

- Be careful not to soil or deform the lamp reflector.

- Make sure that the power of the LCD module is turned off before connecting or

disconnecting cables and connectors.