1.7.2 Battery Charging Control

Battery charging is controlled by a power supply microprocessor. The power supply
microprocessor controls power supply and detects a full charge when the AC adapter and
battery are connected to the computer.

‰ Quick Battery Charge

When the AC adapter is connected, normal charging is used while the system is
turned on and quick charge is used while the system is turned off or in standby mode.
Table 1-12 lists the main battery charging time.

Table 1-12 Time required for charges of main battery

Charging Time

Battery Capacity

Normal charge

Quick charge

Main (4700mAh)

about 3.0 to 13.0

about 3.0

Second (4000mAh)

about 3.0 to 10.5

about 3.0

Quick battery charge is stopped in the following cases.

1. The main battery is fully charged.

2. The main battery is removed.

3. Main battery or AC adapter voltage is abnormal.

4. Charging current is abnormal.

‰ Data preservation time

When turning off the power in being charged fully, the preservation time is as
following Table 1-13.

Table 1-13 Data preservation time

Condition preservation

time

Standby mode

About 6 days

Main (4700mAh)

Boot mode

About 70 days

Standby mode

About 5 days

Second (4000mAh)

Boot mode

About 60 days