beautypg.com

3 check of the raid configuration, 1 explanation of the screen display – Toshiba PORTEGE M400 User Manual

Page 126

background image

3 Tests and Diagnostics

3.3 Check of the RAID configuration

3.3 Check of the RAID configuration

Following screen is displayed for checking the RAID configuration and specifying a failed
drive.

TOSHIBA RAID / RAID Information Display Rev xx.xx.xxxx
Copyright(c) 2005 TOSHIBA CORPORATION. All Rights Reserved.

Level Status

Capacity

LD0 RAID-1 DEGRADE xxGB

Write cache

: Enable

Degrade Bootup

: Yes

MBR Protection

: Disable

S.M.A.R.T

: Enable

Port Assign

Status Size Model Rev

0

LD0-0 ONLINE xxGB xxxxxxx-------------- xxxxxxx

1

LD0-1 FAILED xxGB xxxxxxx-------------- xxxxxxx

< RAID: not OPTIMAL >

3.3.1 Explanation of the screen display

Contents of the screen display are shown below.

Level Status Capacity

LD0 RAID-1

DEGRADE xxGB

Write cache

: Enable

Degrade Bootup

: Yes

MBR Protection

: Disable

S.M.A.R.T

: Enable


Port

Assign Status Size

Model

Rev

0

LD0-0 ONLINE xxGB xxxxxxx--------------

xxxxxxx

1

LD0-1 FAILED xxGB xxxxxxx--------------

xxxxxxx


< RAID: not OPTIMAL >

Physical Drive

information

Logical Drive

information

RAID level

3-8

[CONFIDENTIAL]

PORTEGE M400 Maintenance Manual (960-541)