beautypg.com

Toshiba PORTEGE M400 User Manual

Page 79

background image

2.4 System board Troubleshooting

2 Troubleshooting

PORTEGE M400 Maintenance Manual (960-541)

[CONFIDENTIAL]

2-31

Procedure 3

Diagnostic Test Program Execution Check

Execute the following tests from the Diagnostic Test Menu. These tests check the System
board. Refer to Chapter 3, Tests and Diagnostic, for more information on how to perform
these tests.

1. System test
2. Memory test
3. Keyboard test
4. Display test
5. Floppy Disk test
6. Printer test
7. ASYNC test
8. Hard Disk test
9. Real Timer test
10. NDP test
11. Expansion test
12. CD-ROM/DVD-ROM test
13. Only One test
14. Wireless LAN test
15. LAN/Modem/Bluetooth/IEEE1394 test
16. Sound test

If an error is detected during these tests, go to Procedure 4.

Procedure 4

Replacement Check

The System board connectors may be disconnected. Disassemble the computer following the
steps described in Chapter 4, Replacement Procedures and perform Check 1.

Check 1

Visually check for the following:

a) Cracked or broken connector housing

b) Damaged connector pins

If connectors are in good condition, but there is still a problem, go to Check 2.

Check 2

The System board may be damaged. Replace the System board with a new one
following the steps described in Chapter 4, Replacement Procedures.