11-9-3. Indoor Unit (Other Parts)

Part name

Room temp. (TA) sensor
Heat exchanger (TC) sensor

Checking procedure

Disconnect the connector and measure the resistance value with tester.
(Normal temp.)

Refer to 11-5-1. (5).

Measure the resistance value of each winding coil by using the tester.
(Under normal temp. 25°C)

Remote controller

Louver motor
MP24GA

2

3

Refer to 11-5-1. (3) and (4).

Indoor fan motor

4

5

4

3

2

1

White

Yellow
Yellow
Yellow
Yellow

5

4

3

2

1

No.

1

Red

White

Black

11-9-4. Outdoor Unit

Part name

Compressor
(Model : DA111A1F-20F)

Checking procedure

Measure the resistance value of each winding by using the tester.

Resistance value

380 ± 40

Position

1 to 2
1 to 3
1 to 4
1 to 5

Temperature

Sensor

TA, TC (k

)

10°C

20°C

25°C

30°C

40°C

20.7

12.6

10.0

7.9

4.5

Red

White

Black

Check conduction by using the tester.

Compressor thermo. Bimetal
type (Model : US-
622KXTMQO-SS)

4

Position

Red - White

White - Black

Black- Red

Resistance value

17 to 25k

17 to 25k

17 to 25k

Compressor
(Model : DA130A1F-25F)

Measure the resistance value of each winding by using the tester.

2

Red

White

Black

Outdoor fan motor
(Model : ICF-140-43-4)

Measure the resistance value of each winding by using the tester.

3

Under 20°C

Position

Red - White

White - Black

Black- Red

Resistance value

0.88 to 0.98

0.88 to 0.98

0.88 to 0.98

Position

Red - White

White - Black

Black - Red

Under 20°C

0.69 to 0.77

Resistance value