Toshiba RAS-M13EKCVP-E User Manual

Page 43

background image

– 43 –

Item

4. Capacity

control

Operation flow and applicable data, etc.

Description

1) Indoor unit A and Indoor unit B

determine the respective
instruction revolutions from the
difference between the remote
controller setting temperature
(Ts) and the indoor temperature
(Ta), and transmit this to the
outdoor unit.

2) The outdoor unit receives the

instructions from the indoor
units, and the inverter operates
the compressor at the calculated
revolutions.

3) The compressor operation range

in each operating mode is shown
in the left table.

This function prevents troubles on the electronic parts of
the compressor driving inverter.

This function also controls drive circuit of the compressor
speed so that electric power of the compressor drive circuit
does not exceed the specified value.

1) The input current of the outdoor

unit is detected in the inverter
section of the outdoor unit.

2) According to the detected

outdoor temperature, the
specified value of the current is
selected.

3) Whether the current value

exceeds the specified value or
not is judged.

4) If the current value exceeds the

specified value, this function
reduces the compressor speed
and controls speed up to the
closest one commanded from
the indoor unit within the range
which does not exceed the
specified value.

5. Current release

control

Outdoor temp. To

Setup of current release point

Capacity control continues.

Outdoor temp.

40˚C

7.5A

12.0A

10.1A

10.3A

10.5A

16˚C

39˚C

11˚C

15.5˚C

10.5˚C

Cooling current

release value

Heating current

release value

Current decrease

Outdoor unit inverter main

circuit control current

High

Low

Reduce compressor speed

Operating current

Setup value

Outdoor unit

Operation
mode

No.of
operating unit

Combination of
indoor units

Compressor
revolution (rps)

M18EAV-E
M18EACV-E

Cooling

1 unit

10

13 to 45

13

13 to 71

16

13 to 79

2 units

1 unit

2 units

1 unit

2 units

1 unit

2 units

10

10

15 to 83

13

10

15 to 83

13

13

15 to 83

16

10

15 to 83

M18EAV-E

Heating

10

13 to 76

13

13 to 99

16

13 to 102

10

10

15 to 120

13

10

15 to 120

13

13

15 to 120

16

10

15 to 120

M14EAV-E
M14EACV-E

Cooling

10

13 to 56

13

13 to 74

10

10

18 to 74

13

10

18 to 75

M14EAV-E

Heating

10

13 to 75

13

13 to 80

10

10

16 to 84

13

10

16 to 85

Indoor Unit A

Indoor Unit A

In

Outdoor unit

verter

Compressor