3) Cooling/Heating operation

The operations are performed in the following parts by

controls according to cooling/heating conditions.

1) Receiving the operation ON signal

of the remote controller, the cooling
or heating operation signal starts
being transferred form the indoor
controller to the outdoor unit.

2) At the indoor unit side, the indoor

fan is operated according to the
contents of “2. Indoor fan motor
control” and the louver according to
the contents of “9. Louver control”,
respectively.

3) The outdoor unit controls the

outdoor fan motor, compressor,
pulse motor valve and 4-way valve
according to the operation signal
sent from the indoor unit.

*1. The power coupler of

4-way valve is usually turned on,
and it is turned off during defrost
operation. (Only in heating)

Item

1. Basic

operation

Operation flow and applicable data, etc.

2) Operating mode selection when performing 2-room

operation

Description

1) The outdoor unit operating mode

conforms to the instructions of the
indoor unit that was pressed first.

2) When combined operation consist-

ing of cooling (dry) and heating, fan
(air purification) and heating, or
cleaning operation and heating is
performed, operation conforms to
the instructions of the indoor unit
that was pressed first as shown in
the left table.

3) The indoor fan stops for the indoor

unit that was pressed last and which
instructions are ignored.

Operation ON

Setup of remote controller

Indoor fan motor control
Louver control

Compressor revolution control
Outdoor fan motor control
4-way valve control

In cooling operation: OFF
In heating operation: ON

Pulse motor valve control

Indoor unit

control

Sending of

operation

command signal

Outdoor unit

control

[ ]

No.

Indoor unit

Set operating mode

Actual indoor unit

operation

Actual outdoor

unit operation

1

Indoor unit pressed

Cooling (dry)

Cooling (dry)

Cooling

Indoor unit pressed last

Cooling (dry)

Cooling (dry)

2

Indoor unit pressed

Heating

Heating

Heating

Indoor unit pressed last

Heating

Heating

3

Indoor unit pressed

Fan (solo air

purification)

Fan (solo air

purification)

Stopped

Indoor unit pressed last

Fan (solo air

purification)

Fan (solo air

purification)

4

Indoor unit pressed

Fan (solo air

purification)

Fan (solo air

purification)

Cooling

Indoor unit pressed last

Cooling (dry)

Cooling (dry)

5

Indoor unit pressed

Cooling (dry)

Cooling (dry)

Cooling

Indoor unit pressed last

Fan (solo air

purification)

Fan (solo air

purification)

6

Indoor unit pressed

Cooling (dry)

Cooling (dry)

Cooling

Indoor unit pressed last

Heating

Fan stopped

7

Indoor unit pressed

Heating

Heating

Heating

Indoor unit pressed last

Cooling (dry)

Fan stopped

8

Indoor unit pressed

Fan (solo air

purification)

Fan (solo air

purification)

Stopped

Indoor unit pressed last

Heating

Fan stopped

9

Indoor unit pressed

Heating

Heating

Heating

Indoor unit pressed last

Fan (solo air

purification)

Fan stopped

10

Indoor unit pressed

Cleaning operation

Cleaning operation

Stopped

Indoor unit pressed last

Cleaning operation

Cleaning operation

11

Indoor unit pressed

Cleaning operation

Cleaning operation

Cooling

Indoor unit pressed last

Cooling (dry)

Cooling (dry)

12

Indoor unit pressed

Cooling (dry)

Cooling (dry)

Cooling

Indoor unit pressed last

Cleaning operation

Cleaning operation

13

Indoor unit pressed

Cleaning operation

Cleaning operation

Stopped

Indoor unit pressed last

Fan (solo air

purification)

Fan (solo air

purification)

14

Indoor unit pressed

Fan (solo air

purification)

Fan (solo air

purification)

Stopped

Indoor unit pressed last

Cleaning operation

15

Indoor unit pressed

Cleaning operation

Cleaning operation

Cleaning operation

Stopped

Indoor unit pressed last

Heating

Fan stopped

16

Indoor unit pressed

Heating

Heating

Heating

Indoor unit pressed last

Cleaning operation

Fan stopped