Toshiba RAS-M13EKCVP-E User Manual
Page 104
– 104 –
No.
Remarks
Procedures
Part name
High voltage
generator
"
1) Insert the high voltage generator straight into the
evaporator, and secure it using the fixing screw.
2) Pass the leads of the high voltage generator
through the area designated and insert them into
its connectors.
3) Attach the air ionizer to the back body, and pass
the two leads (black) through the area desig-
nated on the electric parts box assembly.
4) Attach the drain guide.
Check whether
the leads have
been completely
inserted.
Claw
Claw
Claw
This manual is related to the following products: