beautypg.com

2. out door unit (in ver ter assembl y ), Control blok diagram (outdoor unit) – Toshiba RAS-M13EKCVP-E User Manual

Page 33

background image

– 33 –

8-2.

Out

door Unit (In

ver

ter Assembl

y

)

RAS-M14EA

V

-E,
RAS-M18EA

V

-E (Heat pump models)

RAS-M14EA

CV
-E,
RAS-M18EA

CV
-E (Cooling-onl

y models)

220–240 V ~50Hz

220 V ~60Hz

CONTROL BLOK DIAGRAM (Outdoor unit)

Driver circuit of P.M.V.

Noise

filter

Relay

RY701

Converter

(AC

DC)

Input current

sensor

4-way

valve

A unit

P.M.V.

Unit A

send/receive

circuit

Unit B

send/receive

circuit

B unit

P.M.V.

Inverter

(DC

AC)

Gate drive

circuit

Gate drive

circuit

Inverter

(DC

AC)

Outdoor

fan motor

Compressor

MCC-5015 (SUB P.C.B)

MCC-5009 (SUB P.C.B)

Current

detect

Current

detect

M.C.U

• Inverter output frequency control

• A/D converter function

• P.M.V. control

• Discharge temp. control

• Error displey

• Signal communication to MCU

M.C.U

• PWM synthesis function

• Input current release control

• IGBT over-current detect control

• Outdoor fan control

• High power factor correction control

• Signal communication to MCU

Gas side pipe

temp. sensor

(unit B) (TGb)

Gas side pipe

temp. sensor

(unit A) (TGa)

Outdoor Heat-

exchanger temp.

sensor (TE)

Discharge temp.

sensor (TD)

Suction temp.

sensor (TS)

Outdoor air temp.

sensor (TO)

P.M.V : Pulse Motor Valve
PWM : Pules Width Modulation
IGBT : Insulated Gate Bipolar Transistor
*1

: Heat Pump Model Only

High power factor

correction circuit

*1

*1