– 52 –

Item

15. Clean

operation

Operation flow and applicable data, etc.

Description

1. Purpose

The clean operation is to minimize

the growth of mold, bacteria etc. by
running the fan and drying so as to
keep the inside of the air condi-
tioner clean.

Clean operation

When the cooling or dry operation

shuts down, the unit automatically
starts the clean operation which is
then performed for the specified
period based on duration of the
operation which was performed
prior to the shutdown, after which
the clean operation stops. (The
clean operation is not performed
after a heating operation.)

2. Operation

1) When the stop signal from the

remote controller is received, the
S.CLEAN indicator (green) on the
main body lights, and the clean
operation starts. (Neither the
OPERATION indicator nor the
TIMER indicator light.)

2) The period of the clean operation is

determined by the duration of the
operation performed prior to the
reception of the stop code.

3) After the clean operation has been

performed for the specified period,
the unit stops operating.

• During clean operations: The louver opens slightly.

The indoor fan operates continuously at a speed of
260 rpm.

Clean operation times

• To stop an ongoing clean operation at any time

Press the start/stop button on the remote controller
twice during the clean operation. (After pressing the
button for the first time, press it for the second time
without delay (within 10 minutes).)

Unit now performing cooling or
dry operation

Push "stop" button

Only S.CLEAN indicator lights,
and clean operation starts

Time set now elapses

Operation stops

Operation mode

Operation time

Cooling:
Auto (cooling)
Dry

Heating:
Auto (heating)

Auto (fan only)

Shutdown

Up to 10 minutes

From 10 minutes
up to 1 hour

1 hour or longer

No clean operation performed

Clean operation time

No clean operation
performed (0 minutes)

2 hours

4 hours