beautypg.com

Wiring diagram, 1. indoor unit – Toshiba RAS-M13EKCVP-E User Manual

Page 22

background image

– 22 –

MAIN P

.C.

BO

ARD

(MCC-5020)

HEA

T EXCHANGER

SENSOR (TC)

CN07 (WHI)

CN13 (WHI)

CN100 (WHI)

CN08 (WHI)

MCC-899

Wireless Unit Assembly

POWER SUPPLY

CIRCUIT

2
1

4
3

BLK

1

2

3

4

5

6

7

8

9

1

2

3

4

5

6

7

8

9

BLU

BLK

BLU

BLU

BLU

BLU

BLU

BLU

BLU

10

10

9

8

7

6

5

4

3

2

1

9

8

7

6

5

4

3

2

1

CN01 (BLU)

CN10 (WHI)

1

2

1

2

THERMO SENSOR

(T

A)

BLK

BLK

BLK

CN03 (WHI)

1

2

1

2

WHI

1

2

3

4

5

1

2

3

4

5

1

2

1

2

1

2

3

4

5

1

2

3

4

5

LOUVER MO

T

O

R

F

AN MO

T

O

R

INDOOR

TERMINAL

BLOCK

DC MO

T

O

R

WHI

YEL

YEL

YEL

YEL

FUSE

F01

1

3

4

5

1

3

4

5

RED

BLK

WHI

YEL

66

BLU

DC5V

DC12V

DB01

CN21

CN23

CN34

CN22

A

C

250V

BLK

WHI

2
1

3

1

3

RED

GRN &

YEL

T3.15A

Heat

e

xchanger

Micro SW

BR

W

BLU

(RED)

LINE

FIL

TER

TNR

CN33 (WHI)

BLK

1

2

3

4

1

2

3

4

1

2

3

4

1

2

3

4

RED

BRW

BRW

BRW

Ion electrode

High-voltage

Power supply

Air purifier

Electrode

1

2

3

4

5

6

1

2

3

4

5

6

To outdoor unit

Color

Identification

RED
WHI
BLK
BLU
BRW
ORN
PUR
YEL
GRY
PNK
GRN&
YEL

:
:
:
:
:
:
:
:
:
:

:

RED
WHITE
BLACK
BLUE
BROWN
ORANGE
PURPUL
YELLOW
GRAY
PINK
GREEN&
YELLOW

5. WIRING DIAGRAM

5-1. Indoor Unit

RAS-B10EKVP-E, RAS-B13EKVP-E, RAS-B16EKVP-E (Heat pump models)

RAS-M10EKCVP, RAS-M13EKCVP-E, RAS-M16EKCVP-E (Cooling-only models)