– 91 –

11-7. Trouble Diagnosis by Outdoor LED

For the outdoor unit, the self-diagnosis is possible by
five LEDs (Red).

• LEDs (Red) (D11 to D15) are provided on the sub-

control board under surface of the inverter, and as
shown below, they are checked from the wiring port
when removing the wiring cover.

(1) If a trouble occurs, LED (Red) goes on according

to the trouble as described in the table below.

(2) When two or more troubles occur, LEDs go on

cyclically.

(3) Usually, LEDs (Red) go off.

D09 D10 D11 D12 D13

LED (Red)

Contents

Indoor alarm

code

LED indication

D09

D10

D11

D12

D13

Normal running

None

IGBT short circuit, Compressor motor rear short

14

Trouble on position detecting circuit

16

Trouble on current detecting circuit

17

CONDENSOR PIPE TEMP. SENSOR(TE) fault

18

SUCTION PIPE TEMP. SENSOR(TS) fault

18

DISCHARGE PIPE TEMP. SENSOR(TD) fault

19

Trouble on outdoor fan

1A

OUTDOOR TEMP. SENSOR(TO) fault

1B

Trouble on compressor system

1C

GAS SIDE PIPE TEMP. SENSOR a (TGa) fault

1C

GAS SIDE PIPE TEMP. SENSOR b (TGb) fault

1C

TGa, TGb sensor out of place, PMV fault

1C

Communication trouble between MCU

1C

Compressor lock

1D

Trouble on discharge temp. Gas leakage

1E

Compressor break down

1F

: LED ON,