Remote controller

Indoor unit

Control contents of remote controller
• ON/OFF (Air conditioner/Air purifier)
• Operation select

(COOL/HEAT/AUTO/DRY)

• Temperature setup
• Air direction
• Swing
• Air volume select

(AUTO/LOW/LOW+/MED/MED+/HIGH)

• ECO
• ON timer setup
• OFF timer setup
• High power

Signal

receiving

Indoor unit

control

Indoor unit control
• Command signal generating

function of indoor unit operation

• Calculation function

(temperature calculation)

• Activation compensation

function of indoor fan

• Cold draft preventive function
• Timer function
• Indoor heat exchanger

release control

• Clean function

Operation

command

Serial signal

send/receive

• Indoor fan motor
• Louver motor

Outdoor unit

Outdoor unit control
• Frequency control of inverter output
• Waveform composite function
• Calculation function

(Temperature calculation)

• AD conversion function
• Quick heating function
• Delay function of compressor reactivation
• Current release function
• GTr over-current preventive function
• Defrost operation function

• Compressor
• Outdoor fan motor
• 4-way valve
• Pulse motor valve (PMV)

Selection

of operation

conditions

ON/OFF

Serial signal

send/receive

Outdoor unit

control

Inverter

~

Item

1. Basic

operation

Operation flow and applicable data, etc.

1) Operation control

Receiving the user’s operation condition setup, the opera-

tion statuses of indoor/outdoor units are controlled.

Description

1) The operation conditions are

selected by the remote controller as
shown in the left.

2) A signal is sent by ON button of the

remote controller.

3) The signal is received by a sensor of

the indoor unit and processed by
the indoor controllers as shown in
the left.

4) The indoor controller controls the

indoor fan motor and louver motor.

5) The indoor controller sends the

operation command to the outdoor
controller, and sends/receives the
control status with a serial signal.

6) The outdoor controller controls the

operation as shown in the left, and
also controls the compressor,
outdoor fan motor, 4-way valve and
pulse motor valve.