beautypg.com

Ethernet timing of xmit signals – Texas Instruments TMS380C26 User Manual

Page 56

background image

TMS380C26
NETWORK COMMPROCESSOR

SPWS010A–APRIL 1992–REVISED MARCH 1993

POST OFFICE BOX 1443

HOUSTON, TEXAS

77251–1443

56

PARAMETER MEASUREMENT INFORMATION

ethernet timing of clock signals

NO.

PARAMETER

MIN

TYP

MAX

UNIT

300

CLKPHS

Pulse duration of TXC

45

ns

301

CLKPER

Cycle time of TXC

95

1000

ns

TXC

300

2.4 V

0.45 V

300

301

Figure 21. Ethernet Timing Of Clock Signals

ethernet timing of XMIT signals

NO.

PARAMETER

MIN

TYP

MAX

UNIT

305

tXDHLD

Hold time of TXD after TXC high

5

ns

306

tXDVLD

Delay time from TXC high to TXD valid and
Delay time from TXC high to TXEN high

40

ns

TXC

TXD

TXEN

305

306

306

2.4 V

0.45 V

2.4 V

0.45 V

Figure 22. Ethernet Timing of XMIT Signals