beautypg.com

Texas Instruments TMS380C26 User Manual

Page 46

background image

TMS380C26
NETWORK COMMPROCESSOR

SPWS010A–APRIL 1992–REVISED MARCH 1993

POST OFFICE BOX 1443

HOUSTON, TEXAS

77251–1443

46

PARAMETER MEASUREMENT INFORMATION

memory bus timing: TMS380C26 resumes control of bus

t

M

is the cycle time of one-eighth of a local memory cycle (31.25 ns minimum)

NO.

PARAMETER

MIN

MAX

UNIT

79

Hold time of MIF output high impedance after MBCKL1 rising edge, bus resume

tM – 13

ns

80

Delay time from MBCLK1 high to MIF output vallid, bus resume

tM + 9

ns

91

Setup time of MBRQ valid before MBCLK1 falling edge, bus resume

24

ns

82

Hold time of MBRQ valid after MBCLK1 low, bus resume

0

ns

83

Setup time of MBGR high before MBCLK1 rising edge, bus resume

29

ns