System common message, System real-time message, Program change – Roland DR-3 User Manual
Page 118: Song position pointer, Song select, Timing clock, Start, Midi implementation
118
MIDI Implementation
●Program Change
Status
Second
CnH
ppH
n = MIDI Channel Number: 0H–FH (ch.1–ch.16)
pp = Program Number: 00H–63H (prog.1–prog.100)
*
MIDI Channel Number is same as drum part channel.
*
Not recognized in case that drum part channel is “OFF”.
*
Recognizing Program Change message, DR-3 switches Drum Kit of the same number as Program Number. Consequently, bass tone
changes as the Drum kit including.
The prog.1–50 correspond to the P01–P50, and the prog.51–100 correspond to the U01–U50.
*
After recognizing a Program Change message, new voices will sound as a switch, but sounding voices will not change then.
■System Common Message
●Song Position Pointer
Status
Second
Third
F2H
llH
mmH
mm, ll = Value: 00 00H–7F 7FH (0–16383)
*
Recognized under stop state of performances in Song Play mode or Style Play mode, and located the start position to play as a Value.
●Song Select
Status
Second
F3H
ssH
ss = Song Number: 00H–63H (1–100)
*
Recognized under stop state of performances in Song Play Mode, and switched song to play.
■System Real-time Message
●Timing Clock
Status
F8H
*
Recognition regards Sync Mode setting as follows:
Sync Mode: AUTO
Starting by receiving Start message (FAH) or Continue message (FBH), performances are synchronized to Timing Clock message
(F8H).
Sync Mode: REMOTE
Not recognized.
Sync Mode: INT
Not recognized.
●Start
Status
FAH