RAD Data comm ASMI-450 User Manual
Page 93

Diagnostics
ASMi-450 Installation and Operation Manual
5-5
Table 5-1. ASMi-450 Alarm Buffer Messages (Cont’d)
Message
Description
Corrective Actions
Alarm
Type
REMOTE REVERSE
POLARITY
Reversed loop polarity has been
detected by the remote ASMi-450
The ASMi-450 continues normal
operation
ON
REMOTE SELF TEST
ERROR
A problem has been detected during
remote ASMi-450 self-test
Repeat self-test, and replace the
ASMi-450 if it fails the self-test
ON
REMOTE SIGNAL
LOSS
Loss of HDSL line input signal at the
remote ASMi-450.
1. Check the HDSL line.
2. Perform self-test on the two
ASMi-450 and replace the
ASMi-450 that fails the self-test
ON/OFF
REMOTE SP-PAR
SWITCH IS ON
Section DEF SP of switch S1 of the
remote ASMi-450 is set ON
If it is no longer necessary to enforce
the default SP-PAR and node
number, change setting to OFF
ON
REMOTE SYNC LOSS
Loss of synchronization on the
HDSL line at the remote ASMi-450
1. Check the HDSL line
2. Perform self-test on the two
ASMi-450 and replace the
ASMi-450 that fails the self-test
ON/OFF