Diagnostics

ASMi-450 Installation and Operation Manual

5-5

Table 5-1. ASMi-450 Alarm Buffer Messages (Cont’d)

Message

Description

Corrective Actions

Alarm

Type

REMOTE REVERSE

POLARITY

Reversed loop polarity has been

detected by the remote ASMi-450

The ASMi-450 continues normal

operation

ON

REMOTE SELF TEST

ERROR

A problem has been detected during

remote ASMi-450 self-test

Repeat self-test, and replace the

ASMi-450 if it fails the self-test

ON

REMOTE SIGNAL

LOSS

Loss of HDSL line input signal at the

remote ASMi-450.

1. Check the HDSL line.

2. Perform self-test on the two

ASMi-450 and replace the

ASMi-450 that fails the self-test

ON/OFF

REMOTE SP-PAR

SWITCH IS ON

Section DEF SP of switch S1 of the

remote ASMi-450 is set ON

If it is no longer necessary to enforce

the default SP-PAR and node

number, change setting to OFF

ON

REMOTE SYNC LOSS

Loss of synchronization on the

HDSL line at the remote ASMi-450

1. Check the HDSL line

2. Perform self-test on the two

ASMi-450 and replace the

ASMi-450 that fails the self-test

ON/OFF