ASMi-450 Control from the Control Port
4-14
ASMi-450 Installation and Operation Manual
Notes
In addition to the parameters listed in Section 3-5, the following parameters can
be programmed only from the terminal:
PWD
Password protection: select YES or NO
LOG_OFF
Idle disconnect time:
NO
automatic session disconnection disabled.
10_MIN
automatic disconnection after ten minutes if no input
data is received by the ASMi-450.
CTS
Determines CTS state:
ON
The CTS line is always ON (active).
=RTS
The CTS line follows the RTS line.
DCD_DEL
With ASMi-450 control port defined as DTE, indicates delay (in
msec) between DCD=ON and the sending of data.
Values: 0, 10, 50, 100, 200, 300 msec.
POP_ALM
Controls the automatic display of alarms in the terminal
YES
The terminal automatically displays every 10
minutes the alarm status (or whenever an alarm
changes state to ON)
NO
The automatic display feature is disabled
DSR
Determines the DSR state:
ON
The DSR line is continuously on. It will switch to
OFF
for five seconds after the DTR line is switched OFF.
DTR
The DSR line tracks the DTR line. When
INTERFACE=DTE, the DSR line will switch to ON
for five seconds when the RI line is ON while the
DTR
line is OFF.
AUXILIARY
Selects the management mode supported by the control port of
DEVICE
the ASMi-450:
TERMINAL
management by means of a supervision terminal.
NMS_SLIP
management by means of Telnet host, or an
SNMP network management station.
6. After the desired parameter values are selected, press
will display the TIME and DATE fields, followed by the ASMi-450 prompt.