Def sp – RAD Data comm ASMI-450 User Manual
Page 71

ASMi-450 Control from the Control Port
ASMi-450 Installation and Operation Manual
4-13
2. The password entry screen appears, e.g.:
NEW PASSWORD (4 to 8 CHARS) =
CURRENT PASSWORD = 'password'
where 'password' is the current password.
3. Type the required password. Carefully check that the specified password has been
indeed typed in, and then press
DATE fields, followed by the ASMi-450 prompt.
Note
Before entering a new password, make sure that the PSWD section of the
ASMi-450 internal switch S1 is not set to ON, because in such a case the default
password (ASMI) is enforced.
DEF SP-----------------------------------------------------------------------------------------
Purpose
Assign values to control port parameters. See Section 3-5 for parameter description and
allowable ranges, and Section 3-7 for practical selection recommendations.
Format
DEF SP
Use
1. Type
DEF SP
2. The first page of the control port parameters data form is displayed. A typical form is
shown below. The form presents the current parameter values as defaults.
SPEED
DATA
PARITY
INTERFACE
CTS
DCD_DEL
DSR
AUTO
8
NO
DCE
=RTS 0_MSEC
ON
3. Change the parameter values as follows:
•
Bring the cursor to the beginning of the first field to be changed by pressing the
space bar.
•
To change the selected field, press F or B to scroll among the available
selections.
•
When the desired selection is displayed, press the space bar to move to the next
field.
4. When done, press
form is shown below.
POP_ALM
PWD
LOG_OFF
AUXILIARY DEVICE
NO
NO
NO
TERMINAL
5. Repeat the procedure given in Section 3 above to select new parameter values.