Diagnostics

ASMi-450 Installation and Operation Manual

5-3

Table 5-1. ASMi-450 Alarm Buffer Messages (Cont’d)

Message

Description

Corrective Actions

Alarm

Type

LOCAL PSWRD

SWITCH IS ON

Section PSWD of switch S1 of the

local ASMI-450 is set to ON

If it is no longer necessary to enforce

the default password and node

number, change setting to OFF

ON

LOCAL REAL TIME

CLOCK BATTERY

FAILURE

The battery that powers the local

ASMi-450 internal real-time clock

when ASMi-450 is not powered has

failed

Have the ASMi-450 repaired

ON

LOCAL RECEIVE

SLIP

A slip has been detected by the local

ASMi-450 in the receive path

Check the selection of clock sources

at the local and remote ASMi-450

units

ON

LOCAL REVERSE

POLARITY

Reserved loop polarity has been

detected by the local ASMi-450

The ASMi-450 continues normal

operation

ON

LOCAL SELF TEST

ERROR

A problem has been detected during

local ASMi-450 self-test

Repeat self-test, and replace the

ASMi-450 if it fails the self-test

ON

LOCAL SIGNAL LOSS

Loss of HDSL line input signal at the

local ASMi-450

1. Check the HDSL line.

2. Perform self-test on the two

ASMi-450 and replace the

ASMi-450 that fails the self-test

ON/OFF

LOCAL SP-PAR

SWITCH IS ON

Section DEF SP of switch S1 of the

local ASMi-450 is set ON

If it is no longer necessary to enforce

the default control port parameters,

change setting to OFF

ON

LOCAL SYNC LOSS

Loss of synchronization on the

HDSL line at the local ASMi-450

1. Check the HDSL line

2. Perform self-test on the two

ASMi-450, and replace the

ASMi-450 that fails the self-test

ON/OFF

LOCAL TRANSMIT

SLIP

A slip has been detected by the local

ASMi-450 in the transmit path

Check the selection of clock sources

at the local and remote ASMi-450

units

ON

REM TRANSMIT SLIP

A slip has been detected by the

remote ASMi-450 in the receive path

Check the selection of clock sources

at the local and remote ASMi-450

units

ON

REM RECEIVE SLIP

A slip has been detected by the

remote ASMi-450 in the receive path

Check the selection of clock sources

at the local and remote ASMi-450

units

ON