ASMi-450 Control from the Control Port

4-24

ASMi-450 Installation and Operation Manual

LOOP -------------------------------------------------------------------------------------------

Purpose

Activate a user-controlled loopback or test on the ASMi-450 (see Section 5-3 for test
and loopbacks descriptions).

Format

LOOP [looptype]

Use

1. To activate the local (L) loopback on the user's port of the local ASMi-450, type:

LOOP L PORT or LP L PORT

2. To activate the remote (R) loopback on the user's port of the remote ASMi-450, type:

LOOP R R PORT or LP R R PORT

3. You will see the time and date, followed by the ASMi-450 prompt.

At any time, you can activate only one loopback If you try to activate a second
loopback, you will see an error message (illegal loop combination). You must deactivate
the other loopback before you can activate the new one.

NODE-------------------------------------------------------------------------------------------

Purpose

Select an ASMi-450 for establishing a control session.

Format

NODE 'node number'

Use

1. To connect to the desired ASMi-450, type:

NODE 'node number'

where 'node number' is the three-digit node number, in the range of 1 through 255.

2. When the addressed ASMi-450 is on-line, it will echo the complete string:

NODEnnn. After you see the echo, type the desired command.

PASSWORD----------------------------------------------------------------------------------

Purpose

Enter the password when prompted to type the password upon the start of a control
session.

Format

PWD'password'

Use

1. When you see the prompt

PASSWORD>

type:

'password'

where '

password

' is the string of four to eight alphanumeric characters that has been

defined by the user (or the default, ASMI, as appropriate).

2. The ASMi-450 sends the current time and date, and then the prompt

ASMI>

is