ASMi-450 Installation and Operation Manual
4-9
4.5 ASMi-450 Command Set Description
This section describes the ASMi-450 commands. The commands are listed in
alphabetical order. The description includes command format, use, and options.
The following notational conventions are used below:
[
]
square brackets indicate optional entry/parameter
'
'
single quotes delimit user entry
CLR ALM --------------------------------------------------------------------------------------
Purpose
Clear the alarm buffer.
Format
CLR ALM [/A]
Use
1. To clear only alarms of the ON type stored in the alarm buffer (see Table 5-1):
CLR ALM
2. To clear all the alarms stored in the alarm buffer (including ON/OFF alarms):
CLR ALM /A
3. You will see the time and date, followed by the ASMi-450 prompt.
CLR LOOP ------------------------------------------------------------------------------------
Purpose
Deactivate the specified user-initiated loopback or test.
Format
CLR LOOP [looptype] or CLR LP [looptype]
Use
1. To deactivate the local (L) loopback on the user's port of the local ASMi-450, type:
CLR LOOP L PORT
2. To deactivate the remote (R) loopback on the user's port of the remote ASMi-450,
type:
CLR LOOP R R PORT
3. You will see the time and date, followed by the ASMi-450 prompt.
4. If no loopback of the specified type is now activated, you will receive ERROR 2.