ASMi-450 Control from the Control Port
4-20
ASMi-450 Installation and Operation Manual
Display
Format
A typical HDSL line status display is shown below.
STATUS OF LINE
ANALOG FRONT END TYPE
= 784K
LOCAL LINE ALARMS = SYNC LOSS
SIGNAL LOSS
OFF
OFF
The fields included in the status information display are listed below:
ANALOG FRONT END TYPE
Displays the nominal data rate on the HDSL line:
784 kbps for ASMi-450/768.
LINE ALARMS
Displays the state of the line alarms on the HDSL
line:
SIGNAL LOSS
ON indicates loss of HDSL
input signal.
SYNC LOSS
ON indicates loss of
synchronization to the HDSL
signal.
DSP ST PORT -------------------------------------------------------------------------------
Purpose
Display status information on the user's port.
Format
DSP ST PORT [Option]
Use
1. To display the current status information for the user's port, type:
DSP ST PORT
Display
Format
A typical user's port status display is shown below.
STATUS OF PORT
INTERFACE TYPE
=
'interface'
LOCAL UNIT ACTIVATED LOOPS
=
LOCAL PORT
REM REM PORT
NO
NO
REMOTE UNIT INITIATED LOOPS =
REM PORT
NO
The fields included in the ASMi-450 status information display are listed below:
TYPE
Displays the type of the user's port interface
('interface' stands for the interface type: V.35,
X.21, RS-422, RS-530, or ETHERNET).
LOCAL UNIT
Displays the state of each type of loopback that
can be activated ACTIVATED LOOPS by
command from the local ASMi-450 unit on either
the local, or the remote unit:
•
LOCAL PORT: local port loopback on the
local unit.
•
REM REM PORT: remote port loopback